Power Outlet N 352
18 May 2016
Power Outlet P 80
18 May 2016

Power Outlet P 100

Use Used for car chassis and trucks
Destination It trains various special aggregates (hydraulic pumps, water pumps, mud pumps, fire brigade stacker, concrete mixer drum, drilling aggregates, etc.). The sockets may be independent of the gearbox or flange mounted on them.
Runtime – 6000 ore – For independent mounting
– Equal to the service life of the gearbox on which it is flushing
Runtime until the capital repair – 3000 ore – For independent mounting
– Equal to the service life of the gearbox on which it is flushing
Maximum transmitted moment 1000 Nm
Type of coupling Crawled or synchronized
Transmission reports i=0.72; i=1; i=1.21
Coupling mode Empty
Coupling command Manual or electropneumatic
The amount of oil – 17 dm³ – Together with the gearbox
– 6.5 dm³ – For independent mounting
Net weight approx. 125 kg
Unction Mixed by bubbling and under pressure
Type of lubrication pump With lobes

Coefficients for calculation of speeds at power outlets

Gearboxes families Gearbox transmission reports Permanent gearbox Permanent gear
GV80;M100
P 100
0.72 1.00 1.21
Numbers of teeth 21/29 29/29 35/29
RD Arb RD Arb The engine speed is multiplied by the coefficient in the table corresponding to the gearbox type and the power take-off resulting in the power take-off speed
5C/S-100 7.53-1.00 50 22 1.38 1.00 0.83
5C/S-100 5.21-1.00 44 28 1.38 1.00 0.83
5C/S-100 5.21-0.71 44 28 1.38 1.00 0.83
9S-125PL 13.38-1.00 41 31 1.38 1.00 0.83
9S-125PR 9.84-0.74 35 36 1.38 1.00 0.83
16S-140PL 13.81-1.00 39 32 1.38 1.00 0.83
16S-160PR 11.66-0.85 44 50 1.38 1.00 0.83